 Other Products >> Infusion Device >> SSP-110 Single channel syringe pump
 
    
Number:
9162230716
Name:
SSP-110 Single channel syringe pump
Spec:
Memo:
Class:
Other Products
 
    Product Readme

1.Freely Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions, which have a wide range of clinical applications.
2.Transfer the message between the Nurse-call System and the pumps.
3.Three working modes: rate mode, time-volume mode, dosage-weight mode.
4.Unique Human Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
5.Have store many brands syringes,Automatically calibration and compatible with any brand of syringes.
6.Large LCD screen displays working status.
7.KVO and Bolus functions.

 

Specifications:

Unique Human Voice Alarm system

The device triggered the human voice prompt and stop injection automatically when there is any malfunction, making the infusion process safer and more reliable.

Rate:

50/60ml Syringe:  0.1ml/h~999.9ml/h   (0.1ml/h step)
1,000ml/h~1,500ml/h   (1ml/h  step)
30ml Syringe: 0.1ml/h~900.0ml/h    (0.1ml/h step)
20ml Syringe:  0.1ml/h~600.0ml/h   (0.1ml/h step)
10ml Syringe:  0.1ml/h~300.0ml/h   (0.1ml/h step)

Flow Rate Accuracy:

Within ±3% (after correct calibration)

Mechanical precision:

Within ±2%

Bolus Rate:

50/60ml Syringe:  1,200ml/h
30 ml Syringe:  720ml/h
20 ml Syringe:  480ml/h
10 ml Syringe:  240ml/h

Purge Rate:

50/60ml Syringe:  1,500ml/h
30ml Syringe:  900ml/h
20ml Syringe:  600ml/h
10ml Syringe:  300ml/h

Volume Limit:

0.1ml~999.9ml

Total Injection
Volume:

0.1ml~9999.9ml (0.1ml step)

Occlusion:

High:   800mmHg ±200mmHg     (106.7kPa±26.7kPa
Medium: 50/600mmHg ±100mmHg  (66.7kPa±13.3kPa
Low:    300mmHg ±100mmHg    (40.7kPa±13.3kPa )

Alarms:

Injection soon finish, end of injection,occlusion, improperly installation of syringe, wrong setting, low battery, syringe loose etc.

Power Source:

AC 100V~240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup

KVO rate:

1ml/h

Fuse:

F1AL/250/60V, 2pcs inside

Power Consumption:

30VA

IP Classification:

IPX4

Equipment Classification:

Class I, internal power supply, Type CF

Operating Condition:

Ambient temperature: +5℃~+40℃;

Relative humidity:

20~90%

Transport & Storage Condition:

Ambient temperature: -30℃~+55℃

Relative humidity:

≤95%

Dimension:

280mm (L) × 210mm (W) × 130mm (H)

Weight:

2.2kg (net weight)

 

Hits:3162  UpdateTime:2012/9/16 【Print】 【Close

 