Ultrasound,Ultrasonic,b scanner,bladder scanner,ECG,Patient Monitor,Ophthalmic,Dentalt,Respirator equipment,Transducer,OCT

      Prouduct list
Ultrasound B Scanner
Ultrasound Color Doppler
Ultrasound Bladder Scanner
Veterinary Ultrasound
Ultrasound Accessories
ECG(Electrocardiograph)
Monitoring/Fetal Doppler
Ophthalmic(UT/OCT)
Other Products
 

 

    Product Show
 Other Products >> Infusion Device >> SP-200 Infusion Pump
 
    
Number:
91621541816
Name:
SP-200 Infusion Pump
Spec:
Memo:
Class:
Other Products
 
    Product Readme

1.Bubble detector and pressure sensor can precisely detect tube air bubbles
2.Unique Voice Alarm system and accurate injection rate make the injection process safer and more reliable.
3.HD LCD display working status.
4.Have store many brands IV sets,Automatically calibration and compatible with any brand infusion sets.
5.Work mode: ml/h and drop/min, and these two modes can switch freely.
6.KVO and Bolus functions.


Specifications:

Unique Human Voice Alarm system

The device triggered the human voice prompt and stop injection automatically when there is any malfunction, making the infusion process safer and more reliable.

Rate:

1ml/h~1,200ml/h

Flow Rate Accuracy:

Within ±5% (after correct calibration)

Mechanical precision:

Within ±2%

Purge Rate:

100ml/h~1,000ml/h (100 ml/h step)

Infusion Volume:

1ml~9999ml

Total Infusion Volume:

0.1ml~9999.9ml

KVO rate:

1ml/h~5 ml/h (1ml/h step)

Occlusion:

High: 800mmHg ±200mmHg (106.7kPa±26.7kPa
Medium: 500mmHg ±100mmHg(66.7kPa±13.3kPa
Low: 300mmHg ±100mmHg (40.7kPa±13.3kPa )

Alarms:

End of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out etc.

Power Source:

AC 100V~240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup

Bubble detector:

Ultrasonic wave detector; detection sensitivity ≥25μL

Fuse:

F1AL/250V, 2 pc inside

Power Consumption:

30VA

Operating Condition:

Ambient temperature: +5℃~+40℃;
Relative humidity: 20~90%
Atmospheric pressure: 86.0kpa~106.0kpa

Transport & Storage Condition:

Ambient temperature: -30℃~+55℃
Relative humidity: ≤95%

Equipment Classification:

Class I, internal power supply, Type CF

 

Hits:2657  UpdateTime:2012/9/16 【Print】 【Close

 

Copyright 2008 Sonostar Electronic  www.sonostar.net  e-mail:sonostar@163.com
Note: Sonostar trademarks is protected by Madrid Treaty.

我要啦免费统计 Please contact me by msn Please contact me by skype Please contact me by yahoo