SM-100 high-tech fetal & fetal/maternal monitor, it offers a reliable, high-performance solution for fetal or fetal/maternal monitoring needs in doctors’ practices, clinics and hospitals, from pre-natal check-ups to antepartum monitoring of high-risk pregnancies.
Feature:
•Foldable 12.1 inch TFT LCD high-brightness screen with a wide viewing angle and large numerics
12 elements / 1 MHz water proof pulse Doppler transducer(option)for accurate detection
•Event marker for easy documentation of events and kick counts
•Fetal Movement Profile (FMP) detects and automatically records gross fetal body movements
•On-screen scrolling for viewing stored fetal traces
•Twin ultrasound monitoring capability
•Configurable audible and flashing fetal heart rate alarms
•Twin signal overlap alarm function
•Built-in high speed thermal printer, printing width can be set to 112mm,150mm and 210mm
•24-hours memory for fetal traces
•Supporting TCP/IP or wireless connection to the central monitoring station
•Internal Li-ion battery power or AC power from external power supply
Structure chart:
•TFT Color display
The monitor has an integrated, folded color TFT display, with a wide viewing angle, providing high resolution data presentation. Fetal and maternal measurements are displayed as large, easy-to-read numerics.
Information such as patient identification, date and time, alarm information, prompt and error message are also clearly shown.
•Transducers
It uses 12 elements / 1 MHz water proof pulse Doppler transducer designed for high acuity care settings. It is reliable, durable, water tight and easy to clean.
•Printer
The Unicare MARS SERIES Fetal/Maternal monitor has an integrated, high resolution thermal printer, and the printing width can be set to 110mm, 150mm and 210mm.
Traces are recorded at either 1, 2, 3 cm/min can be selective.
The monitor prints the time, the date, trace identification symbols and paper speed when first switch on.
•Alerting:
When an alarm limit is exceeded, it is signaled by the monitor in the following ways:
-An alarm tone sounds
-An alarm message is shown on the screen.
-The numeric of the alarming measurement flashes on the screen.
-Alarm Off/Pause Alarms function
Alarm latching / non-latching: Visual, Audible, Visual and audible
•Fetal Monitoring
MARS B SERIES Fetal Monitor offers non-invasive ultrasound, external TOCO facilities measurements and automatic fetal movement actogram
•Monitor Connectors and Interfaces
-VGA: connector of external display.
-Network: TCP/IP series port for easy connection to central monitoring station through modem or LAN cable.
-Power inlet for power supply.
-Transducer socket




SM-100 high-tech fetal & fetal/maternal monitor, it offers a reliable, high-performance solution for fetal or fetal/maternal monitoring needs in doctors’ practices, clinics and hospitals, from pre-natal check-ups to antepartum monitoring of high-risk pregnancies.
Configuration
Feature
Table legend:●Standard ○Optional —Unavailable |
I |
II |
III |
IV |
Single FHR |
● |
● |
● |
● |
Dual-FHR |
— |
● |
— |
● |
TOCO |
● |
● |
● |
● |
Maternal Fetal Movement(MFM) |
● |
● |
● |
● |
Auto Fetal Movement(AFM) |
● |
● |
● |
● |
Fetal Movement Profile(FMP) |
● |
● |
● |
● |
Signal Overlap Alarm |
— |
● |
— |
● |
Maternal ECG(MECG) |
— |
— |
● |
● |
Maternal NIBP(MNIBP) |
— |
— |
● |
● |
Maternal SPO2(MSpO2) |
— |
— |
● |
● |
Maternal Temperature(MTEMP) |
— |
— |
● |
● |
Maternal Respiration(MRESP) |
— |
— |
● |
● |
Maternal Heart Rate(MHR) |
— |
— |
● |
● |
Lithium Battery |
● |
● |
● |
● |
Network (TCP/IP) |
● |
● |
● |
● |
Printer width |
110 mm |
● |
● |
● |
● |
150 mm |
○ |
○ |
○ |
○ |
210 mm |
○ |
○ |
○ |
○ |
VGA |
○ |
○ |
○ |
○ |
Fetal Stimulator |
○ |
○ |
○ |
○ |
Water proof transducer |
○ |
○ |
○ |
○ |
Wall Mount |
○ |
○ |
○ |
○ |
Trolley |
○ |
○ |
○ |
○ |
Physical Specifications |
Dimension and Weight |
Dimension |
36cm (W)*23cm (D)*12cm (H) |
Weight |
5.3kg(excluding accessories) |
Operation Environment |
Power requirements |
AC100-240V , 50/60Hz |
Power |
100VA |
Temperature |
0-40℃ |
Humidity |
0-93% non-condensing |
Fetal/Maternal Performance Specifications |
Performance Specifications |
Display |
12.1 inch (1024×768 pixel) color TFT –LCD |
Indicator |
Visual on-display and integrated, alarm light, audible alarm |
Battery |
Internal rechargeable Li-ion battery,2.0Ah 14.8V |
Alarm |
Visual on-display and integrated, alarm light, audible alarm |
Memory |
24-hours memory for fetal traces |
Printer |
America standard/international standard
Built-in thermal printer (110mm, 150mm, 210mm for option)
1/2/3cm/min real-time printing speed, fast print speed (stored traces) |
Paper |
Z-fold, thermosensitive |
Record Message |
ID, name, age, date, time, print speed etc |
CMS |
Support connecting to central monitoring station through LAN (TCP/IP) or wireless connection |
Fetal/Maternal Technical Specifications |
Ultrasound (FHR) |
Measurement range |
US |
30 to 240 bpm |
Resolution |
Display |
1bpm |
Printer |
1bpm |
jitter@200 bpm |
≤3bpm |
Display update rate |
0.25second |
Beat to bea change(max.) for ultrasound |
28bpm |
US frequency |
1MHz±5%Hz |
TOCO |
Measurement method |
Strain gauge sensor element |
Sensitivity |
1 unit =2.5g |
Resolution |
1 unit |
Measurement range |
500 units |
Baseline setting |
0, 5,10, 15, 20 can be selective |
Update rate |
0.25 second |
Auto offset correction |
3 second after connecting the transducer |
Auto zero adjust |
TOCO value is set to zero negative
following a negative
Measure value for 5 seconds |
Auto Fetal Movement (AFM) |
Technique |
Pulsed doppler ultrasound |
Range |
0-100% |
Resolution |
1% |
Automatic fetal movement actograph |
Manual fetal movement marker |
Maternal NIBP(MNIBP) |
Operation mode |
Manual/automatic/ STAT |
Measurement unit |
mmHg / kPa selectable |
Test interval |
0-480 minutes |
Accuracy |
Max.Std.deviation:8 mmHg(1.1kPa) |
Max. mean Error: ±5mmHg(±0.7kPa) |
Measurement range |
Systolic |
30 to 270 mmHg(4 to 36 kPa) |
Diastolic |
10 to 245 mmHg(1.5 to 32kPa) |
Mean |
20 to 255 mmHg(2.5 to 34kPa) |
Pulse rate range |
20~250bpm |
Over-pressure protection |
Yes |
Maternal ECG (MECG) |
Heart rate range |
0~300bpm |
Resolution |
1bpm |
Accuracy |
±1bpm/ ±1% |
Leads |
I, II, III, avL, avR, avF, V |
Sweep speed |
12.5mm/s, 25mm/s, 50mm/s |
Gain selection |
x 0.25, x0.5 ,x1, x2 |
Operation mode |
diagnostic, monitor, surgery |
Maternal SpO2 (MSpO2) |
Measurement range |
0%-100% |
Resolution |
1% |
Accuracy |
±2% |
Pulse rate range accuracy |
±3bpm |
Maternal Temperature (MTEMP) |
Technique |
Thermistor probe CYSI 400 series |
Measurement range |
0℃-50℃ |
Accuracy |
±0.1℃ |
|
|
|
|
|
|


|