 Other Products >> Ventilator/Anesthesia >> SV-100E Ambulance emergency Medical Ventilator
 
    
Number:
11182332616
Name:
SV-100E Ambulance emergency Medical Ventilator
Spec:
Memo:
Class:
Other Products
 
    Product Readme

 

Used for First-Aid, Ambulance, Emergency situation and patients transport in hospital, it can be used for pediatric and adult patients.
 
A button operation, it is simple to use with digital control and  precise parameters, and contains special self test function to ensure the patient’s safe.
 
It consists of ventilators, 2L Aluminum Oxygen Cylinder, Breathe Circuit, Carrying Package, Special Bracket for ambulance and pressure reducing valve for large oxygen cylinder, etc.
 
1. Specifications

Kinds of modes C,  A/C,  SIMV,  SIGH,  CPAP,  PEEP
Parameters
Range
Remark
Tidal Volume
50~2000 ml
Digital Precise Adjustable
Respiratory Rate
1~100 bpm
Digital Precise Adjustable
O2%
45~100%
Digital Precise Adjustable
Trigger Level
-20~0 hpa
Digital Precise Adjustable
Peak Pressure
0~60 hPa
Digital Precise Adjustable
PEEP
0~20 hPa
Digital Precise Adjustable
SIGH
1~10 times per 100 breath
Digital Precise Adjustable

2. Monitor

Display
Range
Large LCD Screen Data Display
Tidal Volume, O2%, Sigh, Respiratory Rate, Flow,
Pressure (Synchronized Trigger, Peak Airway, CPAP, PEEP )
Large LCD Screen Curve Display
Airway Pressure Time Waveform Display
Alarm Data Display
High/Low Airway Pressure Alarm, Lack of Gas/Power Alarm,
Parameter Error
Other Display
Lock, Charge Indicator, Inspiratory/Expiratory Situation,
DC/AC Power Supply

3.Self Test, Alarm and Protection
. Special Self Test

JOGGER Portable ventilator complies with the latest National standardssuch as YY0600.3-2007ISO9001ISO13485CHINA FDAetc
Circuit Connect Prompt
Remind the operator to connect the breath circuit correctly to access the using state;
Sound Alarm Test
Test sound alarm, to guarantee the reliability using
Gas Pressure Test
Test gas pressure, remind operator to ensure the gas pressure supply
Internal Battery Capacity Test
Test the capacity of the internal battery
Circuit Leakage Test
Test Circuit Leakage, to lest circuit drop off or leak and unexpected situation to happen

. Alarm

JOGGER portable ventilator contains perfect alarm function and response the machine and patient condition timely and effectively.
High Airway Pressure
Low Airway Pressure
Low Battery Voltage Alarm
Low Gas Pressure
Parameter Error
Silence
High Frequency Alarm
 

 
Hits:2779  UpdateTime:2010/11/18 【Print】 【Close

 